| 1. Define the required accuracy | Specified measurement error, including whether it is stated as a percentage of reading, full scale, or a combined error limit. | These expressions are not interchangeable. An error stated as a percentage of full scale can represent a larger relative error at low flow. Review the complete specification and the conditions under which it applies. | What is the maximum acceptable measurement error across the actual operating range, and does the quoted specification include the transmitter and installation effects? |
| 2. Compare repeatability separately | How consistently the instrument produces the same result when the same conditions and measurement are repeated. | Repeatability describes consistency, not closeness to the true value. A meter can be repeatable while still having a consistent bias that requires calibration or correction. | Is repeatability specified independently from accuracy, and under what flow, fluid, and environmental conditions was it determined? |
| 3. Match the technology to the fluid | Fluid conductivity, viscosity, density, cleanliness, gas content, temperature, and pressure. | Electromagnetic meters require electrically conductive liquids. Coriolis meters can measure mass flow and are used with many liquids and gases, but application limits still matter. Turbine meters can be affected by viscosity and flow disturbance; positive-displacement meters are often suited to viscous fluids. | Is the technology suitable for the fluid’s properties and process conditions, including expected changes during operation? |
| 4. Check the full operating range | Minimum and maximum flow, turndown, low-flow performance, and operation near the meter’s stated limits. | Select a meter for the real process range rather than only its peak flow. Accuracy and repeatability may vary with flow rate, and a meter sized too large may perform poorly at normal low flows. | What are the expected minimum, normal, and maximum flows, and are performance specifications available at those points? |
| 5. Review installation requirements | Required straight pipe, flow profile, orientation, vibration, grounding, and upstream or downstream disturbances. | Elbows, valves, pumps, and partially filled pipes can affect some meters. Requirements vary by technology and design; follow the instrument’s installation instructions and consider flow conditioning where needed. | What piping layout and installation conditions are required to achieve the specified performance at this site? |
| 6. Plan calibration and verification | Calibration method, traceability, calibration interval, field verification options, and the availability of suitable reference equipment. | Calibration compares an instrument with a reference under defined conditions; traceability documents the link to recognized measurement standards. The appropriate interval depends on risk, use, history, and applicable regulations—not a universal schedule. | Can the instrument be calibrated or verified in place, what records are provided, and how will the interval be set and reviewed? |
| 7. Evaluate total ownership needs | Materials compatibility, pressure and temperature ratings, cleaning needs, diagnostics, spare parts, support, and lifecycle cost. | Wetted materials and seals must suit the fluid and cleaning process. Consider access for maintenance and whether the measurement output and diagnostics integrate with the control or data system. | What maintenance, cleaning, certification, spare-part, and integration requirements will affect the equipment over its service life? |