| 1 | Handheld Static Field Meter | Surface electrostatic field and calculated voltage | Approximately ±0.1 to ±30 kV at a specified distance | Commonly about ±5% of reading or full scale; resolution may be 1 to 10 V | Usually a fixed distance such as 25 mm or 1 inch | Quick checks of work surfaces, packaging, films, trays, and equipment | Accuracy depends strongly on distance, target size, grounding, and surrounding electric fields |
| 2 | Charged Plate Monitor | Ionizer decay time and ion balance offset | Plate voltage commonly around ±1,000 V; decay measured from a defined starting voltage to a defined ending voltage | Voltage indication often within approximately ±5%; decay-time resolution commonly 0.1 to 1 second | Typically 300 mm or another distance defined by the test method | Verifying ionizer performance, discharge time, and polarity balance | Results are method-dependent and should be compared only when distance, airflow, and starting voltage are consistent |
| 3 | Ion Current Density Meter | Ion current delivered to a collector or sensing electrode | Often from picoampere or nanoampere levels up to several microamperes, depending on the sensor | Typically about ±5% to ±10% of reading; low-current resolution depends on shielding and instrument noise | Use the distance specified by the ionizer manufacturer or internal procedure | Comparing ion output, airflow effects, and performance across multiple ionizer locations | Does not directly equal surface voltage decay unless the charge, geometry, and airflow conditions are controlled |
| 4 | Faraday Cup or Ion Collector | Net ion current entering a collector, usually reported by polarity | Typically picoampere to microampere current measurements | Often approximately ±1% to ±5% of reading after proper zeroing and shielding | Position and orientation should be fixed for repeatable comparisons | Laboratory characterization of positive and negative ion output | Highly sensitive to airflow, electromagnetic interference, contamination, and collector geometry |
| 5 | Electrostatic Voltmeter | Non-contact surface potential | Commonly from several volts to ±20 or ±30 kV, depending on probe and standoff distance | Frequently about ±1% to ±5% of reading under controlled conditions | Requires a controlled probe-to-surface distance, often 1 to 25 mm | Detailed voltage mapping on wafers, films, components, and insulating materials | Measures voltage rather than ion concentration; readings can vary with material thickness and geometry |
| 6 | Ionizer Performance Analyzer | Combined decay time, balance, voltage, and sometimes airflow-related results | Usually supports plate voltages around ±1,000 V and balance ranges from tens to hundreds of volts | Commonly about ±5% for voltage-related measurements; timing resolution often 0.1 second or better | Often 300 mm, 450 mm, or a user-defined distance | Routine qualification, maintenance records, and acceptance testing of ionization systems | More expensive and less flexible than a single-purpose field meter; procedures must be standardized |
| 7 | Data-Logging or Remote Ion Monitor | Continuous electrostatic voltage, ion balance, decay, or environmental trend data | Depends on the installed sensor; many systems cover millivolt-to-kilovolt potential ranges | Often approximately ±2% to ±5% for voltage channels; verify the specification for each sensor | Fixed installation distance and sensor orientation are required | Production-line monitoring, alarms, process control, and traceable quality records | Installation, calibration, sensor placement, and network configuration can affect total measurement uncertainty |