| C-Stud | C-shaped section; common web depths include approximately 50, 64, 70, 92, and 100 mm. Flange widths are commonly around 32–40 mm. | Vertical framing for non-load-bearing partition walls and drywall linings. | Approximately 0.45–1.2 mm, depending on the system and structural requirements. | Match the stud depth to the wall design and insulation thickness. Check spacing, wall height, and any required load or fire-rating specifications. |
| U-Track | U-shaped channel sized to suit the selected stud width; commonly available for stud depths around 50–100 mm. | Top and bottom runners for partition framing; also used as a perimeter track in some lining systems. | Approximately 0.45–1.2 mm, selected to suit the framing system. | Use a track compatible with the stud profile and thickness. Allow for the specified fixing method and movement details at the head of the wall. |
| Hat Furring Channel | Shallow hat-shaped section, often about 22–25 mm deep with a face around 60 mm wide; exact sizes vary by system. | Creates a fixing plane for drywall on walls or ceilings and can help level uneven substrates. | Approximately 0.45–0.8 mm for many non-structural systems. | Check the required stand-off, support spacing, and compatible clips or fasteners. Use a system-rated spacing for the board type and installation orientation. |
| Ceiling Carrying Channel | Metal channel section used as a primary or secondary ceiling member; profile depth and width depend on the ceiling system. | Supports suspended drywall ceilings, typically in conjunction with hangers and furring channels. | Commonly around 0.5–1.0 mm; engineered or heavier-duty systems may require thicker steel. | Choose according to ceiling span, hanger spacing, board layers, service loads, and the manufacturer’s tested system details. |
| Perimeter Angle | Right-angle section; common legs are approximately 25 × 25 mm or 30 × 30 mm. | Supports or finishes the edges of suspended ceilings and provides a perimeter fixing surface. | Approximately 0.4–0.8 mm for common ceiling applications. | Confirm that the leg size suits the ceiling layout and that the angle is compatible with the main ceiling members and perimeter fixing substrate. |
| Resilient Channel | Shallow, offset metal channel; overall depth is commonly around 12–18 mm, with profile dimensions varying by system. | Separates drywall from framing to reduce direct vibration transmission in some wall and ceiling assemblies. | Approximately 0.45–0.6 mm in many standard products. | Use only in a tested acoustic assembly. Follow the specified orientation, fastener locations, spacing, and board-layer details; incorrect installation can reduce performance. |
| Steel Corner Bead | Perforated or expanded-metal angle with two wings, often around 25–32 mm per side. | Reinforces external drywall corners and provides a straight edge for joint compound. | Approximately 0.3–0.5 mm for many light-gauge corner beads. | Select a bead suited to the corner detail and finishing method. Confirm the wing size, corrosion protection, and compatibility with the compound or finish system. |
| Selection note: Dimensions and steel thicknesses are indicative ranges, not universal specifications. Actual sizes, coatings, tolerances, and load capacities vary by local standards and framing system. Verify project drawings, applicable codes, and tested system documentation before ordering or installation. |