| Food and beverage processing | Milk, juice, process water, and cleaning-in-place (CIP) circuits | 316L stainless steel; titanium may be considered for chloride-rich service | EPDM for suitable hot-water and CIP duties; select only after checking the fluid and cleaning chemicals | Hygienic, cleanable passages; confirm plate finish and channel arrangement meet process and sanitation requirements | Check product compatibility, cleaning temperatures, chloride levels, drainage, and applicable food-contact requirements |
| District heating and building services | Hot water, heating-water loops, and domestic hot-water circuits | 316L stainless steel for many closed-water duties; titanium where water chemistry warrants it | EPDM is commonly considered for hot-water service, subject to the actual temperature and water treatment | Choose channel geometry to balance heat-transfer performance, pressure drop, and resistance to fouling | Check design pressure and temperature, water chemistry, flow variation, and the required approach temperature |
| Seawater cooling | Seawater on one side and fresh water or process fluid on the other | Titanium is widely used for seawater-wetted plates; higher-alloy stainless steels require careful chloride assessment | EPDM or another qualified elastomer, selected for the full temperature and fluid exposure | Consider fouling, service access, and channel velocity within the equipment maker’s allowable limits | Check seawater temperature, chlorination, deposits, crevice-corrosion risk, and the material of all wetted parts |
| Chemical processing | Acids, alkalis, solvents, and mixed process streams | 316L, titanium, 254 SMO (UNS S31254), or nickel-chromium-molybdenum alloy (UNS N10276), depending on chemistry | EPDM, NBR, or FKM, chosen only after compatibility review for the specific chemical mixture | Use a plate and gasket combination matched to both streams; consider a double-wall arrangement where cross-contamination risk matters | Verify concentration, temperature, impurities, oxidizing conditions, pressure, and gasket compatibility using corrosion data |
| Oil and gas processing | Produced water, utility cooling, and selected hydrocarbon duties | 316L or higher-alloy stainless steel; titanium or nickel alloys may be required for specific corrosive streams | NBR may suit some oil services; FKM or other qualified elastomers may be considered for particular fluids and temperatures | Assess fouling and solids, cleanability, flow distribution, and whether a plate-and-frame design is suitable for the duty | Check hydrocarbons, sour-service conditions, chlorides, solids, pressure cycling, and all applicable project specifications |
| Pulp and paper | Process water, white water, and selected chemical or utility streams | 316L stainless steel for compatible streams; higher-alloy materials may be needed for corrosive chemicals | EPDM or another material selected for the process fluid and cleaning regime | Allow for suspended fibers and deposits; evaluate channel spacing and access for cleaning | Check solids loading, fiber content, scaling tendency, chemical exposure, and cleaning frequency |
| Power generation and utility cooling | Closed-loop cooling water, condensate, and auxiliary heat-recovery duties | 316L stainless steel for suitable treated-water service; titanium for seawater or other compatible aggressive cooling media | EPDM is often considered for water service; confirm its temperature and chemical limits for the duty | Match thermal performance with allowable pressure drop and operating turndown; plan for inspection and maintenance | Review water treatment, dissolved oxygen, chlorides, scaling, design conditions, and applicable pressure-vessel rules |
| Refrigeration and heat pumps | Water, brine, glycol mixtures, and refrigerant-related duties in suitable exchanger configurations | 316L stainless steel is common for compatible aqueous circuits; material choice for refrigerant service depends on design and fluid | EPDM or another refrigerant- and fluid-compatible gasket, where a gasketed design is applicable | Confirm suitability for the specific exchanger configuration, low-temperature operation, and required pressure rating | Check refrigerant or brine compatibility, freeze protection, pressure, temperature range, and local code requirements |