| 1. Single-Phase Wi-Fi MCB | Apartments, lighting circuits, sockets, and small appliances | 1P+N; typically 16–63 A | 220–240 V AC; 50/60 Hz | 2.4 GHz Wi-Fi; mobile app and voice-platform integration may be available | Overload and short-circuit protection; remote ON/OFF; energy monitoring on selected models | DIN rail; commonly aligned with IEC 60898-1; verify local certification | Cost-conscious residential automation |
| 2. Zigbee Smart MCB | Multi-room homes and buildings using a central smart-home hub | 1P+N or 2P; typically 16–63 A | 220–240 V AC; 50/60 Hz | Zigbee 3.0; requires a compatible gateway or hub | Remote switching, schedules, overload alerts, and optional current or power data | DIN rail; check compliance with IEC 60898-1 and regional radio requirements | Reliable low-power mesh networks |
| 3. Energy-Monitoring Smart MCB | Home energy management and load-reduction programs | 1P+N or 2P; typically 20–63 A | 220–240 V AC; 50/60 Hz | Wi-Fi, Bluetooth commissioning, or gateway-based communication | Voltage, current, power, power factor, cumulative energy, and overload protection | DIN rail; measurement accuracy is commonly specified as Class 1 or better, depending on design | Users who need consumption data rather than switching only |
| 4. Smart RCBO with Residual-Current Protection | Bathrooms, kitchens, outdoor circuits, and other higher-risk areas | 1P+N; typically 6–40 A | 220–240 V AC; 50/60 Hz | Wi-Fi or Zigbee, depending on the model | Overload, short circuit, and residual-current protection; common trip sensitivity is 30 mA | DIN rail; typically evaluated against IEC 61009-1; local RCD requirements must be checked | Personal protection combined with remote control |
| 5. Two-Pole Smart MCB | Single-phase feeders, water heaters, HVAC, and dedicated equipment | 2P; typically 40–100 A | 220–240 V AC; 50/60 Hz | Wi-Fi, Ethernet gateway, or RS-485-based system integration | Simultaneous switching of line and neutral; remote trip status and optional energy metering | DIN rail; interrupting capacity and coordination must match the installation design | High-load single-phase circuits |
| 6. Three-Phase Smart Breaker | Small commercial sites, pumps, workshops, and three-phase equipment | 3P or 4P; typically 16–63 A | 380–415 V AC between phases; 50/60 Hz | Ethernet, RS-485/Modbus, Wi-Fi, or cellular gateway | Phase voltage, current, power, energy, phase imbalance, and remote trip monitoring | DIN rail or panel installation; verify IEC 60947-2 suitability and local approval | Commercial and light-industrial distribution |
| 7. Matter- or Cloud-Connected Smart Breaker | New smart-home installations requiring broader platform compatibility | 1P+N or 2P; typically 16–63 A | 220–240 V AC; 50/60 Hz | Matter over Wi-Fi or Thread, or proprietary cloud connectivity; verify ecosystem support | Remote switching, schedules, fault alerts, and optional real-time energy data | DIN rail; confirm electrical safety certification, cybersecurity policy, and regional radio approval | Cross-platform smart-home projects and future expansion |