| 12 V automotive blower motor | 0–16 V DC | 0–50 A; select continuous capacity for the measured load | 0–6,000 rpm | 0–1 N·m | Check both no-load and loaded operation. The required range depends on the blower design and test fixture. |
| 12 V windshield wiper motor | 0–16 V DC | 0–30 A, with suitable transient measurement for startup or stall tests | 0–200 rpm at the output shaft | 0–15 N·m at the output shaft | Specify whether speed and torque are measured at the motor shaft or the geared output shaft. |
| 12 V starter motor | Adjustable supply covering approximately 9–16 V DC | Typically 0–1,000 A for brief cranking or load tests; provide a separate continuous-current rating | 0–6,000 rpm at the motor shaft, if speed measurement is required | 0–50 N·m, subject to the starter design and test method | Starter current can be very high and test duration is usually limited. Use appropriately rated cables, sensors, protection, and fixtures. |
| 24 V automotive auxiliary motor | 0–32 V DC | 0–100 A for many component tests; increase the range for high-power loads | 0–10,000 rpm | 0–10 N·m | Suitable examples include auxiliary pumps and fans; confirm the actual motor’s rated and peak values. |
| 48 V mild-hybrid or auxiliary drive motor | 0–60 V DC, with adequate transient margin | 0–300 A, selected according to the motor’s continuous and peak current | 0–20,000 rpm | 0–100 N·m | Verify voltage transients, sensor bandwidth, regenerative operation, and the dynamometer’s power capacity. |
| High-voltage traction motor, approximately 400 V class | Test system rated for the specified DC bus; a 0–500 V DC range may suit some setups | Common test-system ranges include 0–500 A; higher-power systems may require more | 0–20,000 rpm | 0–500 N·m | For inverter-fed motors, define whether voltage means DC-link voltage or AC line-to-line output voltage. Use equipment designed for hazardous high-voltage testing. |
| High-voltage traction motor, approximately 800 V class | Test system rated above the maximum specified DC bus; a 0–1,000 V DC range may suit some setups | Set from the motor and inverter limits; 0–1,000 A is a possible system range for higher-power testing | 0–25,000 rpm, if required by the motor specification | 0–1,000 N·m, depending on the motor and dynamometer | Confirm insulation, isolation, overspeed protection, energy recovery, and the continuous and peak ratings of every test-system component. |
| Key Sizing Checks |
| Voltage range and measurement | Choose a range that covers the motor’s maximum operating voltage and expected transients. Confirm whether the tester measures DC bus voltage, phase voltage, or line-to-line RMS voltage. |
| Current range and overload | Check continuous current, peak current, peak duration, and sensor bandwidth separately. A tester’s short-duration peak rating does not mean it can carry that current continuously. |
| Speed and torque capacity | The speed sensor and dynamometer must cover the motor’s full operating range. Match torque capacity to the expected load and verify that the dynamometer can safely absorb or return the resulting power. |
| Power cross-check | For rotational power, use P (kW) = torque (N·m) × speed (rpm) ÷ 9,549. Check the calculated power against the continuous and peak ratings of the motor, dynamometer, and test system. |
| Safety and test conditions | Use suitable guarding, emergency stops, overspeed protection, electrical isolation, and interlocks. The ranges above are practical selection examples, not universal motor specifications; confirm them against the motor data sheet and test procedure. |