| Clear, low-solids aqueous feed | <0.01 g/L | 1–2 mPa·s | 4–12 L/min/m² | 5–9 | Single-stage graded-depth cartridge or sheet with a relatively fine final layer. | 0.5–5 µm | Use a lower flow rate when turbidity or product value is high. Confirm compatibility with the filter medium and housing. |
| Lightly turbid process water | 0.01–0.10 g/L | 1–3 mPa·s | 3–10 L/min/m² | 6–9 | Coarse-to-fine depth stages; place the coarser layer upstream to extend service life. | 1–10 µm | Monitor differential pressure and replace the element when the pressure limit specified by the equipment design is reached. |
| Moderate suspended solids | 0.10–1.00 g/L | 1–5 mPa·s | 2–8 L/min/m² | 5–10 | Multi-stage depth filtration, normally beginning with a more open pre-layer or reusable screen. | 5–25 µm | Estimate solids loading over the complete batch, not only the initial concentration. A larger filtration area may reduce replacement frequency. |
| High-solids slurry | 1–10 g/L | 2–20 mPa·s | 0.5–4 L/min/m² | 4–10 | Use a coarse pre-separation step followed by a thick, high-capacity depth medium. | 10–50 µm | depth filters alone may have limited capacity. Consider settling, centrifugation, or a screen before fine clarification. |
| Low-viscosity solvent or oil-like feed | <0.10 g/L | 2–20 mPa·s | 1–8 L/min/m² | Not applicable or solvent-dependent | Choose a depth medium and seal material rated for the specific solvent, temperature, and pressure conditions. | 1–20 µm | Verify wetting behavior, extractables, swelling, and chemical compatibility before scale-up. Do not assume water compatibility applies to solvents. |
| Viscous liquid or concentrated solution | 0.01–1.00 g/L | 20–500 mPa·s | 0.1–2 L/min/m² | 4–10 | Use a larger filtration area, an open-grade depth stage, and controlled temperature where the product permits. | 5–50 µm | Higher viscosity increases pressure loss and reduces throughput. Flow tests should be performed at the actual operating temperature. |
| Acidic aqueous feed | 0.01–1.00 g/L | 1–10 mPa·s | 1–8 L/min/m² | 2–5 | Use a depth medium, housing, and elastomers with documented resistance to the actual acid concentration and temperature. | 1–25 µm | pH alone does not define compatibility; acid type, concentration, temperature, exposure time, and cleaning chemicals are also critical. |
| Alkaline aqueous feed | 0.01–1.00 g/L | 1–10 mPa·s | 1–8 L/min/m² | 9–13 | Select an alkali-resistant medium and verify the complete filter assembly for caustic cleaning conditions. | 1–25 µm | Check fiber, binder, adhesive, gasket, and housing materials independently; the weakest component determines system compatibility. |
| Biological or fermentation broth | 0.10–10 g/L | 1–50 mPa·s | 0.5–4 L/min/m² | 4–8 | Use staged clarification with a high-capacity coarse depth medium before any fine polishing stage. | 10–50 µm | Foaming, compressible solids, and shear sensitivity can strongly affect performance. Validate with representative broth rather than water. |
| High-purity final clarification | <0.01 g/L after prefiltration | 1–5 mPa·s | 1–6 L/min/m² | Product-dependent | Use a fine final depth stage only after upstream solids reduction and prefiltration. | 0.2–1 µm | Define the required particle-removal performance, microbial-control objective, extractables limit, and validation method before selection. |