| 1 | Voltage | Match the battery pack voltage to the equipment’s specified operating range. | A common lithium-ion cell is approximately 3.6–3.7 V nominal and 4.2 V when fully charged. A 3-series pack is approximately 10.8–11.1 V nominal and 12.6 V fully charged. | An incorrect voltage can cause poor performance, equipment damage, or a charging fault. |
| 2 | Capacity | Compare the required runtime with the battery’s capacity in ampere-hours or watt-hours. | Energy in watt-hours can be estimated as: Wh = nominal voltage × Ah. For example, a 12 V, 20 Ah pack stores approximately 240 Wh before conversion losses. | Higher capacity generally provides longer runtime, but it may also increase size, weight, and charging time. |
| 3 | Dimensions | Measure the available length, width, and height, including cable exits and mounting hardware. | Record the enclosure dimensions in millimeters and allow additional room for connectors, wiring bends, service access, and ventilation. | A pack that meets electrical requirements may still be unusable if it cannot physically fit or be serviced. |
| 4 | Weight | Check the maximum permitted battery weight for the application and mounting structure. | Lithium battery packs commonly provide roughly 100–220 Wh/kg at pack level, depending on chemistry, enclosure, protection, and design. | Lower weight improves portability and vehicle efficiency, while a heavier enclosure may improve protection and durability. |
| 5 | Continuous and Peak Current | Compare the equipment’s normal and startup current with the battery and BMS ratings. | Select a continuous current rating above the expected operating current and verify the duration of any peak or surge current. | Insufficient current capability can cause voltage drop, BMS shutdown, overheating, or reduced service life. |
| 6 | Connectors and Cables | Confirm connector type, polarity, cable gauge, locking method, and current rating. | The connector and cable should be rated for the required continuous current, with secure strain relief and clearly identified positive and negative terminals. | Correct connectors reduce installation errors, contact resistance, accidental disconnection, and heat buildup. |
| 7 | Battery Management System | Verify protection against overcharge, over-discharge, overcurrent, short circuit, and excessive temperature. | The BMS must be compatible with the cell chemistry, series count, charge voltage, continuous current, and application temperature range. | A suitable BMS helps keep cells balanced and limits operating conditions that can create safety risks. |
| 8 | Installation Space | Evaluate clearance, mounting points, ventilation, cable routing, and access for inspection. | Do not compress, puncture, or place the pack near strong heat sources. Follow the manufacturer’s specified clearances and mounting orientation. | Correct installation reduces vibration, mechanical damage, overheating, and difficult maintenance. |
| 9 | Charging Requirements | Use a charger designed for the exact battery chemistry, series configuration, and charging voltage. | Common lithium-ion packs use a constant-current/constant-voltage charging profile. Lithium iron phosphate packs require a different voltage profile. | The wrong charger can reduce capacity, shorten battery life, or create a serious safety hazard. |
| 10 | Environment and Safety | Check operating temperature, humidity protection, vibration resistance, storage conditions, and transport requirements. | Many lithium battery packs operate near 0–45 °C while charging and approximately −20–60 °C while discharging, but the exact limits vary by cell and pack design. | Matching the environment helps prevent condensation, capacity loss, premature aging, and unsafe operation. |