| 1 | Rock-wool partition specialist | Coated steel facings with a mineral-wool core | 50–150 mm | Cleanroom walls where fire performance is a priority | Fire-test classification, core density, joint detailing, and facing finish |
| 2 | EPS-core panel producer | Color-coated steel facings with an expanded-polystyrene core | 50–100 mm | General-purpose partitions in controlled environments | Fire performance, core quality, flatness, and sealed panel joints |
| 3 | PU-core panel producer | Metal facings bonded to a polyurethane foam core | 50–100 mm | Temperature-controlled rooms and insulated clean areas | Thermal performance, fire-test evidence, and compatibility with room conditions |
| 4 | PIR-core panel producer | Metal facings with a polyisocyanurate foam core | 50–100 mm | Insulated cleanroom envelopes and temperature-controlled spaces | Product-specific fire test results, joints, and declared thermal data |
| 5 | Aluminum-facing panel fabricator | Aluminum sheet facings with a selected insulation core | 50–100 mm | Lightweight partitions and areas requiring corrosion-resistant facings | Aluminum alloy and thickness, coating, impact resistance, and edge protection |
| 6 | Stainless-steel-facing panel fabricator | Stainless-steel facings over an insulation core | 50–100 mm | Hygienic areas subject to frequent cleaning or demanding chemical exposure | Steel grade, sheet thickness, surface finish, and cleaning-chemical compatibility |
| 7 | Paper-honeycomb panel fabricator | Metal facings with a paper-honeycomb core | 50–100 mm | Lightweight partitions where high insulation or fire performance is not the primary requirement | Moisture exposure, load requirements, edge sealing, and applicable fire requirements |
| 8 | Gypsum-core panel fabricator | Metal facings with a gypsum-based core | 50–100 mm | Interior partitions where a rigid, smooth surface is required | Moisture suitability, panel weight, fire documentation, and joint sealing |
| 9 | Cleanroom ceiling-panel fabricator | Insulated sandwich panels with ceiling-compatible joints and support details | 50–100 mm | Suspended or supported cleanroom ceilings | Span and support design, service cut-outs, load limits, and airtightness |
| 10 | Custom-cut panel fabricator | Project-specified facings and core, with factory-cut openings or shaped edges | Project-specific; commonly 50–150 mm | Rooms requiring doors, windows, pass-throughs, or equipment openings | Approved shop drawings, dimensional tolerances, reinforced openings, and sealed cut edges |