| 11–15 kV | Local medium-voltage distribution to neighborhoods, commercial areas, and industrial customers. | Compact indoor or outdoor substations are common, with distribution transformers stepping voltage down for local use. | Metal-enclosed switchgear, circuit breakers, protection relays, and distribution transformers are typical. Insulation and clearances are lower than at transmission voltages. |
| 22–35 kV | Primary distribution and sub-transmission; often supplies large customers or feeds lower-voltage distribution networks. | Equipment is generally larger than at 11–15 kV, while many installations can still use compact switchgear arrangements. | Load-break switches or circuit breakers, instrument transformers, surge arresters, and step-down transformers are selected for the system’s rated voltage and fault level. |
| 66–69 kV | Sub-transmission and regional supply, particularly in networks that use this level to connect distribution areas. | Outdoor air-insulated layouts are common; some sites use gas-insulated equipment where space is limited. | Greater phase-to-phase and phase-to-ground clearances are needed than at distribution voltages. Busbars, breakers, disconnectors, and protection systems are sized for network conditions. |
| 110–138 kV | Sub-transmission and transmission connections between regional substations and load centers. | Substations typically require larger yards or more compact high-voltage switchgear, plus power transformers for voltage conversion. | High-voltage circuit breakers, disconnectors, instrument transformers, surge arresters, and coordinated insulation design are important. |
| 220–230 kV | Bulk transmission between major generation, transmission, and load-center substations. | Higher insulation levels and longer electrical clearances influence the size and layout of outdoor yards; bus arrangements are designed for reliability and maintenance. | High-capacity breakers, busbars, current and voltage transformers, protection relays, and transformer bays are typical. Switching overvoltages and lightning protection must be considered. |
| 345–400 kV | High-capacity transmission across regions and between major grid nodes. | Equipment spacing, insulation coordination, and substation footprint increase. Gas-insulated substations may be used where land is constrained. | Extra-high-voltage breakers, disconnectors, instrument transformers, surge arresters, and carefully designed grounding systems are required. |
| 500–765 kV | Long-distance, high-capacity transmission on some large interconnected grids. | Very large clearances and specialized insulation and switching design shape the substation layout. These installations are less common and typically serve major transmission corridors. | Equipment must address high electrical stresses, switching transients, and corona effects. Shunt reactors or other reactive-power equipment may be used to help manage voltage on long lines. |